DCVG stands for Direct Current Voltage Gradient and is a survey technique used for assessing the effectiveness of corrosion protection on buried steel structures. In particular, oil and natural gas pipelines are routinely monitored using this technique to help locate coating faults and highlight deficiencies in their cathodic protection (CP) strategies. PDR( Portable DC Rectifier) is air cooled cathodic protection test rectifier, is a portable cathodic protection power supply used for a variety of CP field test scenarios. Provided with a 30 volt, 10 amp maximum DC output, and solid state variable interrupter, the PDR is capable of providing a wide range of portable DC power.
Items | Specification | Related Standard | |
---|---|---|---|
H/W | PDA | M3 MOBILE | MOBILECOMPIA MODEL:MC-7500S |
DCVG BOARD | 8-Bit Micro Controller | ||
18-Bit ADC | 2.048V ±0.05% ACCURACY | ||
CIPS BOARD | 8-Bit Micro Controller | ||
16-BIT ADC (Input Range) | ±20 V | ||
REFERENCE ELECTRODE ELECTRODE | MCM LINE OF ELECTRODE | MODEL RE-5 : 2EA | |
S/W | CRACK FINDER | .NET Compact Framework | Windows Mobile 5.0 |
POWER & SIZE | USING VOLTAGE | MCB-6000S PDA BATTERY | LI-ION BATTERY |
SIZE (HEIGHT) | 1200 | Unit ( mm ) |
Items | Specification | Related Standard | |
---|---|---|---|
H/W | Portable Rectifier | DC 30V / 10A | |
Interrupter | Sample Rate : 0.1 ~ 99sec SSR : DC250 / 15A |
||
Measuring | Range: +10 V ~ + 10 V | ||
UMPC | OS : Wince6.0 CPU : 32Bit RISC CPU 533Mz LCD : 7 Inch(800x480), Touch Screen |
||
Interface(Remote Control) | LTE/WIBRO/LAN/CDMA/Bluetooth | ||
AC/ Battery | AC 110~ 220 | ||
Battry : 5 Hours | |||
Charging Time : 7 Hours | |||
S/W | Smart App.(Remote Control & Monitoring) | ||
POWER & SIZE | 517(L) x 433(W) x 200(H) / 13.5 Kg | Unit ( mm ) |